Tripp Lite N392B-61M-3X8AP 40/100G Singlemode 9/125 OS2 Fiber Optic Cable (3x8F MTP/MPO-APC F/F), LSZH, Yellow, 61 m (200 ft.)
SKU
N392B-61M-3X8AP
£942.48
£785.40
Out of stock
40/100G Singlemode 9/125 OS2 Fiber Optic Cable (3x8F MTP/MPO-APC F/F), LSZH, Yellow, 61 m (200 ft.)
40/100 GbE Cable Supports Higher Bandwidths Needed for High-Density Data Networking
As the amount of traffic in data networks grows, so does the need for devices and fiber cables to support higher bandwidths for high-density patching between data center MDFs and IDFs in enterprise installations. This singlemode 9/125 OS2 cable is an ideal choice for 100G Ethernet applications up to 100 meters (328 feet) at 1550 nm. It is also backward compatible with 10 Gb and 25 Gb networks, so you can future-proof your current application for an eventual upgrade to 100 Gb.
100% Tested for Low Insertion Loss and Back Reflection
The factory-terminated 8-fiber MTP/MPO APC connectors help minimize back reflection with low insertion loss. The connector’s slim boot and green housing allow easy one-handed installation and removal of the cable.
Yellow Jacket Helps Avoid Misidentification That Can Cause Costly Downtime
The OS2-rated cable has a yellow jacket to identify it as singlemode in a crowded patch panel or switch and prevent it from becoming accidentally disconnected. The round low-smoke zero-halogen (LSZH) jacket limits the amount of toxic smoke emitted in case of combustion, making it suitable for poorly ventilated areas.
As the amount of traffic in data networks grows, so does the need for devices and fiber cables to support higher bandwidths for high-density patching between data center MDFs and IDFs in enterprise installations. This singlemode 9/125 OS2 cable is an ideal choice for 100G Ethernet applications up to 100 meters (328 feet) at 1550 nm. It is also backward compatible with 10 Gb and 25 Gb networks, so you can future-proof your current application for an eventual upgrade to 100 Gb.
100% Tested for Low Insertion Loss and Back Reflection
The factory-terminated 8-fiber MTP/MPO APC connectors help minimize back reflection with low insertion loss. The connector’s slim boot and green housing allow easy one-handed installation and removal of the cable.
Yellow Jacket Helps Avoid Misidentification That Can Cause Costly Downtime
The OS2-rated cable has a yellow jacket to identify it as singlemode in a crowded patch panel or switch and prevent it from becoming accidentally disconnected. The round low-smoke zero-halogen (LSZH) jacket limits the amount of toxic smoke emitted in case of combustion, making it suitable for poorly ventilated areas.
SKU | N392B-61M-3X8AP |
---|---|
EAN | 0037332272225 |
Manufacturer | Eaton |
PDF Url | https://objects.icecat.biz/objects/m |
AVAILABILITY | N |
Technical details | |
---|---|
Jacket material | Low smoke zero halogen (LSZH) |
Fiber mode structure | Single-mode |
Connector 1 | 3x MTP/MPO |
Connector 2 | 3x MTP/MPO |
Cable length | 61 m |
Core diameter | 9 µm |
Cladding diameter | 125 µm |
Insertion loss | 0.7 dB |
Sustainability compliance | Yes |
Sustainability certificates | UL ECOLOGO |
Master (outer) case GTIN (EAN/UPC) | 10037332272222 |
Compliance certificates | CE, REACH, RoHS |
Features | |
Bending radius | 2 cm |
Fibre optic type | OS2 |
Jacket material | Low smoke zero halogen (LSZH) |
Fiber mode structure | Single-mode |
Connector 1 | 3x MTP/MPO |
Connector 2 | 3x MTP/MPO |
Cable length | 61 m |
Core diameter | 9 µm |
Cladding diameter | 125 µm |
Operating temperature (T-T) | -20 - 60 °C |
Storage temperature (T-T) | -20 - 60 °C |
Insertion loss | 0.7 dB |
Data transfer rate | 400 Gbit/s |
Country of origin | China |
Ethernet interface type | 10 Gigabit Ethernet, 40 Gigabit Ethernet, 100 Gigabit Ethernet, 400 Gigabit Ethernet |
Wavelengths supported | 1550 nm |
Harmonized System (HS) code | 8544.70.0000 |
Product colour | Black, Green, Yellow |
Connector 2 gender | Female |
Connector 1 gender | Female |
Connector polish type | APC |
Data transmission | |
Data transfer rate | 400 Gbit/s |
Operational conditions | |
---|---|
Operating temperature (T-T) | -20 - 60 °C |
Storage temperature (T-T) | -20 - 60 °C |
Weight & dimensions | |
Bending radius | 2 cm |
Cable length | 61 m |
Package width | 362 mm |
Package depth | 431.8 mm |
Package height | 44.4 mm |
Package weight | 1.22 kg |
Packaging data | |
Package width | 362 mm |
Package depth | 431.8 mm |
Package height | 44.4 mm |
Package weight | 1.22 kg |
Quantity per pack | 1 pc(s) |
Logistics data | |
Master (outer) case width | 320 mm |
Master (outer) case length | 381 mm |
Master (outer) case height | 325.1 mm |
Master (outer) case gross weight | 6.71 kg |
Products per master (outer) case | 5 pc(s) |
Harmonized System (HS) code | 8544.70.0000 |
Quantity per pack | 1 pc(s) |